摘要
目的 分析医院感染暴发疫情特点,探讨疫情发生原因。方法 采集医院感染病例咽拭子、血清标本和病房外空调循环水、房间的沐浴水、医生办公室以及屋顶空调系统循环水,对咽拭子和血清标本检测嗜肺军团菌IgM和流感病毒核酸,采集的水样培养嗜肺军团菌。采用血清间接免疫荧光法检测嗜肺军团菌IgM定性和细菌培养定量;逆转录聚合酶链反应检测流感病毒核酸及分型等。结果 本次疫情病例均发生在医院内分泌科,累计报告10例患者,以呼吸道症状为主,疫情持续9 d,患者年龄在71~ 87岁,主要为住院病人,共6例;医护人员发病4例,年龄在24~ 37岁。患者血清嗜肺军团菌IgM抗体(+)7例;冷凝水、循环水和咽试子标本嗜肺军团菌培养均为阴性;流感病毒核酸阳性5例(甲型H3N2)。结论 此次事件可能是由嗜肺军团菌合并普通季节性流感病毒感染引起的医院感染暴发疫情。
Abstract
Objective The characteristics of nosocomial infection outbreak were analyzed and the causes were discussed. Methods Pharyngeal swabs, serum samples and air conditioning circulating water outside the ward, bath water in the room, circulating water in the doctor's office and roof air conditioning system were collected in hospital infection cases. IgM of legionella pneumophila and influenza virus nucleic acid were detected in pharyngeal swabs and serum samples, and the water samples were collected for the culture of legionella pneumophila.Serum indirect immunofluorescence assay was used to determine IgM and bacterial culture of legionella pneumophila.Reverse transcription polymerase chain reaction (PCR) was used to detect nucleic acid and genotyping of influenza virus. Results All the cases of this epidemic occurred in the endocrinology department of the hospital, and 10 patients were reported in total, mainly respiratory symptoms. The epidemic lasted for 9 days, and the patients were 71 to 87 years old, mainly hospitalized patients, a total of 6 cases.There were 4 cases of illness among medical staff, aged 24~ 37 years.Serum IgM antibody (+) of legionella pneumophila in 7 patients; The culture of legionella pneumophila in condensed water, circulating water and pharynx samples was negative. Influenza virus nucleic acid positive in 5 cases (H3N2). Conclusion This may be an outbreak of nosocomial infection caused by legionella pneumophila combined with common seasonal influenza virus infection.
关键词
医院感染 /
嗜肺军团菌 /
流感 /
疫情暴发
Key words
Hospital infection /
Legionella pneumophilus /
Flu /
Outbreak
王玉, 贺士军, 杨汶桢, 李钰, 田永琴.
贵阳市某医院疑似嗜肺军团菌合并流感病毒感染暴发疫情的调查报告[J]. 安徽预防医学杂志. 2019, 25(1): 33-35
WANG Yu, HE Shijun, YANG Wenzhen, LI Yu, TIAN Yongqin.
Investigation report on outbreak of suspected legionella pneumophila combined with influenza virus infection in a hospital in guiyang city[J]. Anhui Journal of Preventive Medicine. 2019, 25(1): 33-35
{{custom_sec.title}}
{{custom_sec.title}}
{{custom_sec.content}}
参考文献
[1] 贾辅忠,主编.医院内感染-监控与管理[M].南京:江苏科学技术出版社,1990:12.
[2] 中华人民共和国卫生部. 医院感染暴发报告及处置管理规范[M].北京:中华人民共和国卫生部,2009.
[3] 中华人民共和国卫生部. 流感样病例暴发疫情处置指南(2012版)[M].北京:中华人民共和国卫生部,2012.
[4] 中华人民共和国卫生部.流行性感冒诊断与治疗指南(2011 版)[M].北京:中华人民共和国卫生部,2011.
[5] 中华人民共和国卫生部.公共场所集中空调通风系统卫生规范(2012版)[M].北京:中华人民共和国卫生部,2012.
[6] 冯文如.军团菌在空调系统中的传播和控制[J].中国人兽共患病学报,2006,22(1):78-80.
[7] 张琦,陈小东.军团菌与军团菌病研究进展[J].江苏预防医学,2012,23(4):40-43.
[8] 李蝉媛.2012~2016年铁岭市公共场所集中空调冷却水、冷凝水嗜肺军团菌检测结果分析[J].中国卫生检验杂志,2018,28(1):120-123.
[9] 罗俊明,罗如平.105例儿童甲型H 1N 1流感病例流行病学与临床特征分析[J].实用预防医学,2011,18(2):258-260.