微波消解-砷铈催化分光光度法测定母乳中碘含量

李四生, 宋晓琼, 葛成相, 戴震, 李家涛

安徽预防医学杂志 ›› 2016, Vol. 22 ›› Issue (3) : 156-157.

PDF(748 KB)
PDF(748 KB)
安徽预防医学杂志 ›› 2016, Vol. 22 ›› Issue (3) : 156-157.
论著

微波消解-砷铈催化分光光度法测定母乳中碘含量

  • 李四生, 宋晓琼, 葛成相, 戴震, 李家涛
作者信息 +

Determination of iodine in breast milk by microwave digestion - arsenic cerium catalytic spectrophotometry

  • LI Si-sheng, SONG Xiao-qiong, GE Cheng-xiang, DAI Zhen, LI Jia-tao
Author information +
文章历史 +

摘要

目的 探索建立测定母乳中碘含量的前处理和检测方法。方法 母乳样品经HNO3-H2O2体系微波消解后,用砷铈催化分光光度法测定消解液中的碘含量。结果 乳汁碘浓度在0~300 μg/L范围内相关系数大于0.9999,最低检测浓度为8 μg/L(取样量5.00 ml);高、中、低三种浓度相对标准差(RSD)<4%;回收率为86.5%~102.6%, 900份母乳碘含量测定结果平均值为169.2 μg/L。结论 微波消解-砷铈催化分光光度法测定母乳中碘含量,该方法具有灵敏度高、准确性好、重现性好等特点,适用于母乳中碘含量的测定。

Abstract

Objective To explore and establish the pretreatment and determination of iodine in breast milk. Methods The breast milk samples were digested by a mixture of concentrated nitric acid and hydrogen peroxide (HNO3- H2O2 ) in the sealed vessel, then the iodine in digestion solution was subjected to the analysis by arsenic cerium catalytic spectrophotometry. Results The standard curve range of iodine concentration was 0-300 μg/L, the correlation coefficient of standard curve was more than 0.9999,the minimum detectable concentration was 8 μg/L (Sampling volume of 5.00 ml), the recovery of standard addition was between 86.5% and 102.6%, and the relative standard deviation of high, medium and low concentration was less than 4%. The average iodine of 900 breast milk was 169.2 μg/L. Conclusion The method of microwave digestion-arsenic cerium catalytic spectrophotometry determination of iodine in breast milk could digest the sample thoroughly and this method had good reproducibility, high sensitivity, and good accuracy, suitable for the determination of iodine in breast milk.

关键词

微波消解 / 砷铈催化分光光度法 / 母乳 / 检测方法 / / 碘缺乏病

Key words

Microwave digestion / Arsenic cerium catalytic spectrophotometry / Breast milk / Detection method / Iodine / Iodine efficiency disorders

引用本文

导出引用
李四生, 宋晓琼, 葛成相, 戴震, 李家涛. 微波消解-砷铈催化分光光度法测定母乳中碘含量[J]. 安徽预防医学杂志. 2016, 22(3): 156-157
LI Si-sheng, SONG Xiao-qiong, GE Cheng-xiang, DAI Zhen, LI Jia-tao. Determination of iodine in breast milk by microwave digestion - arsenic cerium catalytic spectrophotometry[J]. Anhui Journal of Preventive Medicine. 2016, 22(3): 156-157
中图分类号: R174   

参考文献

[1] 张颖,李俞莹,姚旋,等.碘与甲状腺疾病[J].生命科学,2012,24(8):901-908.
[2] 王甫军.探析碘缺乏病防治有效性[J].中国农村卫生,2015,72(18):70.
[3] 江雪萍.新疆北疆地区尿碘含量异常儿童干预效果评价[J].中国卫生检验杂志,2013,23(12):2655-2656.
[4] 左书梅,张晓燕,马凤改,等. 电感耦合等离子体-质谱法快速测定尿中的碘[J] .光谱实验室,2013,30(6):3100-3101.
[5] 陆龙根,钱亚玲,卢秀静. 海带中碘成分分析标准物质的研制[J].卫生研究,2004,33(5):618-619.