Comparison of two disinfection methods for surface of high frequency contact objects in ICU

LIU Anyun, SHEN Ru, SHENG Hong, ZHONG Feng, FANG Yongmei, ZHANG Binhua, DAI Jun

Anhui Journal of Preventive Medicine ›› 2020, Vol. 26 ›› Issue (1) : 19-22.

PDF(865 KB)
PDF(865 KB)
Anhui Journal of Preventive Medicine ›› 2020, Vol. 26 ›› Issue (1) : 19-22. DOI: 10.19837/j.cnki.ahyf.2020.01.006

Comparison of two disinfection methods for surface of high frequency contact objects in ICU

  • LIU Anyun, SHEN Ru, SHENG Hong, ZHONG Feng, FANG Yongmei, ZHANG Binhua, DAI Jun
Author information +
History +

Abstract

Objective To analyze the disinfection effect of two disinfection methods in general intensive care unit (ICU),and to discusse the disinfection method with reliable disinfection effect,convenient operation and good compliance. Methods From February to December 2018,the inpatients in the general ICU of the Second Affiliated Hospital of Wannan Medical College were randomly divided into group A and group B according to their bed units,with 30 beds in each group.Group A was disinfected with 500 mg/L chlorine containing disinfectant,group B was disinfected with compound quaternary ammonium salt wipes,and the bed fence,bedside table and electrocardiograph monitor panel were wiped and disinfected.The disinfecting effect,time consumption and compliance of different disinfecting methods were compared. Results The sterilization rate and qualified rate of two disinfection methods on the object surface of inpatients in ICU decreased with time,but there was no significant difference in disinfection effect between the two groups (P>0.05).The disinfection time of group A was (34.92±3.06) minutes longer than that of group B.The disinfection compliance of group A and group B was 52.32% and 81.30% respectively,and that of group B was significantly higher than that of group A (χ2= 260.308,P<0.05). Conclusion The disinfectant effect of compound quaternary ammonium salt wipes on the surface of high frequency contact objects in ICU was reliable,easy to use,high compliance,and could reduce the risk of cross contamination,which was worth popularizing.

Key words

Compound quaternary ammonium salt wipes / ICU / High frequency contact surface / Disinfection effect

Cite this article

Download Citations
LIU Anyun, SHEN Ru, SHENG Hong, ZHONG Feng, FANG Yongmei, ZHANG Binhua, DAI Jun. Comparison of two disinfection methods for surface of high frequency contact objects in ICU[J]. Anhui Journal of Preventive Medicine. 2020, 26(1): 19-22 https://doi.org/10.19837/j.cnki.ahyf.2020.01.006

References

[1] Martin-Loeches I,Diaz E,Valles J.Risks for multidrug-resistant pathogens in the ICU[J].Curr Opin Crit Care,2014,20(5):516-524.
[2] Brusselaers N,Vogelaers D,Blot S.The rising problem of antimicrobial resistance in the ICU.Ann Intensive Care,2011,1(47): 1-7.
[2] Strich JR,Palmore TN.Preventing transmission of multidrug-resistant pathogens in the intensive care unit[J].Infect Dis Clin North Am,2017,31(3): 535-550.
[4] 中华人民共和国国家卫生和计划生育委员会:WS/T 509-2016.重症监护病房医院感染预防与控制规范[S].2017.
[5] 中华人民共和国国家质量监督检验检疫总局,中国国家标准化管理委员会: GB 15982 -2012.医院消毒卫生标准[S].2012.
[6] Hayden MK,Blom DW,Lyle EA,et al.Risk of hand or glove contamination after contact with patients colonized with vancomycin-resistant enterococcus or the colonized patients’ environment[J].Infect Cont Hosp Ep,2008,29(2):149-154.
[7] Huang S,Datta R,Platt R.Risk of acquiring antibiotic-resistant bacteria from prior room occupants[J].Jama Inter Med,2006,166(18):1945.
[8] 陈焕红.伽玛湿巾与含氯消毒剂用于多重耐药菌消毒的效果及经济学分析[J].中国药物经济学,2016,11(4):9-11.
[9] 孙兰,邹梅,张晶莹,等.复合双链季铵盐消毒液的毒性研究[J].中国卫生工程学,2008,7(3):136-138.
[10] Engelbrecht K,Ambrose D,Sifuentes L,et al.Decreased activity of commercially available disinfectants containing quaternary ammonium compounds when exposed to cotton towels[J].Am J Infect Control,2013,41(10):908-911.
[11] Bloss R,Meyer S,Kampf G.Adsorption of active ingredients of surface disinfectants depends on the type of fabric used for surface treatment[J].J Hosp Infect,2010,75(1):56-61.
[12] Sifuentes LY,Gerba CP,Weart I,et al.Microbial contamination of hospital reusable cleaning towels[J].Am J Infect Control,2013,41(10):912-915.
[13] Sastre J,Madero MF,Fernandez-Nieto M,et al.Airway response to chlorine inhalation (bleach) among cleaning workers with and without bronchial hyper responsiveness[J].Am Journal Ind Med,2011,54(4):293-299.
[14] 谭昆,谭莉,韩颖,等.消毒湿巾对新生儿病房环境物体表面消毒的效果[J].中国感染控制杂志,2018,17(6):480-484.
[15] 杨锡瑶,胡小骞,吴贻乐,等.三种消毒方法对医院物体表面消毒效果观察[J].中国消毒学杂志,2018,35(1):20-22.
PDF(865 KB)

Accesses

Citation

Detail

Sections
Recommended

/