Objective To develop a simple method of assaying microdose iodine in the fingernails. Methods The samples were digested by perchloric acid and potassium perchlorate and the iodine content of the sample was determined by arsenic cerium catalytic spectrophotometry.The linearity and liner near range of the standard curve,detection limit,precision,recovery rate of the newly developed arsenic cerium catalytic spectrophotometry were tested. Results The linear range of this method was 0~200μg/L,|R|≥0.9999.The detection limit is 1.29μg/g and the quantification limit is 4.30μg/g (sample 0.3ml).The inter assay coefficient of variation (CV)for one sample was 0.84%.The nails of the high,medium,and low iodine content groups were added sample and recovered.The adding sample amount was 2ng,15ng,and 20ng respectively.and the recovery rate was 105.4%. Conclsion The method has good precision and accuracy.The experimental method is simple and easy to operate.It can be used as a detection method of micro iodine in human nails.
Key words
Iodine /
fingernail /
Arsenic cerium catalytic spectro-photometry
{{custom_sec.title}}
{{custom_sec.title}}
{{custom_sec.content}}
References
[1] 苏晓辉,刘鹏,申红梅,等.《2016碘与甲状腺疾病大会共赏》的解读[J].中华地方病学杂志,2017, 36(2):81-86.
[2] WHO/UNICEF/ICCIDD.Assessment of iodine deficiency disorders and monitoring their elimination.A guide for programme managers[R].Third edition, Geneva: WHO Press, 2007:28-34.
[3] Horn-Ross PL,Morris JS,Lee M,etal.Iodine and thyroid cancer risk among women in a multiethnic population: the Bay Area Thytoid cancer Study[J].Cancer EpidemiolBiomaker Prev,2001,10(9):979-985.
[4] Ren Y,Kitahara CM,Berrington de Gonzalez A,et al.Lack of Association between Fingernail Selenium and Thyroid Cancer Risk:A Case-Control Study in FrenchPolynesia[J].Asian Pac J Cancer Prev,2014,15(13):5187-5194.
[5] 卫生部.研制生物样品监测检验方法指南(WS/T 68-1996)[S].北京:中国标准出版社,1996.
[6] Li C,Peng S,Zhang X, et al.The urine iodine to creatinine as an optimal index of iodine during pregnancy in an Iodine adequate area in China[J].J ClinEndocrinolMelab, 2016, 101(3):1290-1298.
[7] 郝文,乔虹.人体碘含量检测方法的应用[J].中华地方病学杂志,2017,36(11):851-855.
[8] SC/T 3010-2001,海带中碘含量测定.
[9] 刘云,纪雅菲,何雪玲,等.大学生头发中金属元素含量测定及分析[J].微量元素与健康研究,2018,35(3):54-56.
[10] 徐斌,肖德强,肖晶莹.学龄前儿童膳食营养素摄入与头发微量元素的相关性分析[J].2018,25(10):1169-1171,1183.
[11] 吴良.砷铈接触法测定人发中的微量碘[J].海南医学院学报,2006,12(1):28-30.
[12] 张亚平,黄淑英,李呐,等.砷铈催化光度法测定血清碘的样品消化方法[J].中华检验医学杂志 2017,40(2):119-125.
[13] 陆征,姜鹏,纪晓红,等.高氯酸一氯酸钠消解法测定血清碘的方法学研究[J].中华地方病学杂志,2016,35(9):690-694.