Study of manganese determination in human blood by graphite furnace atomic absorption spectrometry

TANG Yu-fei, WANG Lei, LIU Bi-yong, ZHANG Jing, WANG Gui-feng

Anhui Journal of Preventive Medicine ›› 2016, Vol. 22 ›› Issue (5) : 312-314.

PDF(857 KB)
PDF(857 KB)
Anhui Journal of Preventive Medicine ›› 2016, Vol. 22 ›› Issue (5) : 312-314.

Study of manganese determination in human blood by graphite furnace atomic absorption spectrometry

  • TANG Yu-fei, WANG Lei, LIU Bi-yong, ZHANG Jing, WANG Gui-feng
Author information +
History +

Abstract

Objective To develop an easy and stable method of manganese determination in human blood by graphite furnace atomic absorption spectrometry (GFAAS). Methods By optimizing the experimental conditions of graphite temperature and proportions of matrix modifiers, the standard addition method was used to determine the manganese in blood. Results Under the optimal conditions, the determination limit for blood manganese was 0.5 μg/L. The absorbance showed linear to the manganese concentration in the range of 1.0~20.0 μg/L and the correlation coefficient was over 0.9990. Conclusion The method with high sensitivity and good accuracy is easy and rapid, which is suitable for determination of manganese in blood.

Key words

Graphite furnace / Atomic absorption spectrometry (AAS) / Blood / Manganese

Cite this article

Download Citations
TANG Yu-fei, WANG Lei, LIU Bi-yong, ZHANG Jing, WANG Gui-feng. Study of manganese determination in human blood by graphite furnace atomic absorption spectrometry[J]. Anhui Journal of Preventive Medicine. 2016, 22(5): 312-314

References

[1] 杨心乐, 王桂兰, 张忠诚. 锰与人体健康[J]. 医学综述, 2006, 12(18):1134.
[2] 陈祖义. 核素示踪技术研究稀土元素147Pm、141Ce和147Nd的环境毒理与安全性[J]. 核农学报, 2004 18 (1): 36-42.
[3] 杨君, 茆文革, 朱宝立. 江苏省正常人群血锰、血铅负荷水平调查[J]. 江苏预防医学, 2012, 23(2): 31-33.
[4] 刘成武, 黄汉林, 李娟, 等. 广东省正常人群全血中锰、钴、硒参考值调查[J]. 中国职业医学, 2012,39(3): 197-201.
[5] 王凯,魏明至,郑晓梅, 等. 辽宁省一般人群血和尿中锰水平研究[J]. 中国工业医学杂志, 2016, 29(1):12-15.
[6] 丁春光, 朱醇, 刘德晔, 等. 电感耦合等离子质谱方法检测全血中30种金属及类金属元素[J]. 中华预防医学杂志, 2012, 46(8): 745-749.
[7] 冯立顺, 刘洪燕. 石墨炉原子吸收法测定金属过程中常用基体改进剂的效用分析[J]. 福建分析测试, 2007,16(3): 46-48.
PDF(857 KB)

Accesses

Citation

Detail

Sections
Recommended

/